Advanced Search
 
 
 
Browse by Category
 
 
 
Featured Brands
 
 
Dell DELLM0003 400V Metered Pdu 4J1C2
We apologize but this item is currently unavailable. Please feel free to browse our website for other available items.
Enlarge
Item Code:
PDUDELLCN04J1C2
Manufacturer:
Model:
DELLM0003 4J1C2 CN-04J1C2
Item Condition Description:
This unit is new and includes a Ground Wire Kit, Button Mount Kit with Screws, 1x Serial to RJ45 cable, and Manuals with Installation Guides.
Item Description

Dell DELLM0003 400V 50/60Hz 16A 11.5kW 21x IEC320-C13 6x IEC320-C19 Vertical Metered Rack Power Distribution Unit PDU 4J1C2 04J1C2 CN-04J1C2.

Dell Part Number:
4J1C2 04J1C2 CN-04J1C2
Model Number:
DELLM0003







Features:

The Dell Metered Rack PDU distributes power to the devices in the rack.
Outlets - The Rack PDU has (21) IEC 320-C13 and (6) IEC 320-C19 outlets.
Power Cord - The Rack PDU attached power cord terminates with a 5-pin, 3, IEC60309 plug, 516P6S

Includes:

- 1x Grounding Wire Kit TP3T1 0TP3T1 CN-0TP3T1
- 1x Serial to RJ45 Cable
- Button Mount Kit with Screws
- Manuals with Installation Guides
- 1x DELLM0003 PDU











Specifications:

Electrical
Input connection:  IEC60309-16 A plug
Acceptable input voltage: 346–415 VAC ± 10%
Maximum input current (phase): NA: 20 A (16 A UL(C-UL) derated); INTL: 16 A
Input frequency: 50/60 Hz
Output voltage: 200–240 VAC ± 10%
Output connections
- (21) IEC 320-C13
- (6) IEC 320-C19
Maximum output current (outlet)
- C13: 10 A
- C19: 16 A
Maximum output current (phase): NA: 20 A (16 A UL (C-UL) derated); INTL: 16 A
Maximum output current (total all output): NA: 48 A (maximum); INTL: 48 A (maximum)
Maximum output current (external breaker): NA: 20 A; INTL: 16 A

Physical Dimensions (HxWxD)
- 178.0 x 5.6 x 5.1 cm (70.1 x 2.2 x 2.0 in)
- Depth at breakers: 9.3 cm (3.7 in)

Environmental
Maximum elevation (above MSL)
- Operating: 0 to 3048 m (0 to 10,000 ft)
- Storage: 0 to 15 240 m (0 to 50,000 ft)
Temperature
- Operating: 0 to 50°C (32 to 122°F)
- Storage: -15 to 60°C (5 to 140°F)
Humidity
- Operating: 5 to 95% non-condensing
- Storage: 5 to 95% non-condensing

Compliance
Safety approvals: UL(C-UL), TUV-GS, TUV-S Mark, IRAM, South Africa (LoA), GOST, SONCAP, KC, Australia (ESV)
EMC: EN 55022 Class A, CISPR 22 Class A, AS/NZS CISPR 22 Class A, KN 22 Class A, EN 55024, CISPR 24, KN 24, IEC 61000-3-11, IEC 61000-3-12, EU EMC DIRECTIVE 2004/108/EC (most recent revision)
ROHS: Dell 6T198, EU DIRECTIVE 2002/95/EC-latest revision